Product |
Description |
MINDRAY PRODUCTS |
|
PM-8000 Express Patient Monitor
• 8.4” TFT display with maximum 8 waveforms
• Large font display
• SpO2 pulse-tone modulation (Pitch Tone)
• Masimo SET™ / Nellcor OxiMax ™/ Mindray SpO2
• Microstream™ EtCO2 (Oridion) / Sidestream EtCO2 (Mindray)
• External 12v DC input for ambulance transport
• Compact flash slot for wireless LAN or memory card
• Li-ion / lead acid battery
• Networkable with Hypervisor VI Central Monitoring System |
|
BENEVIEW T6/T8
• 15"/17"color TFT display
• Suitable for adult, pediatric and neonatal patients
• Up to 3 slave screens on the main units for separate view
• 13 module slots for flexible configuration
• MPM module with up to 8-hour data saving for
patient
transport • Advanced technologies including RM, ICG, BIS, etc.
• Maximum 8 channels for IBP measurement
• Friendly and configurable user interface
Powerful data review:
• Maximum 120-hour graphic and tabular trends of all
parameters • 24-hour full disclosure waveforms review
• 120 seconds frozen waveforms
• Up to 1000 pieces of NIBP record storage
• 100 pieces of regular alarms review
• 100 pieces of ARR alarms storage
• Ethernet or Wireless LAN networking
|
|
PM-8000 PATIENT MONITOR
• 8.4"TFT display, maximum 5 waveforms
• Parameters including ECG/RESP, SpO2, NIBP, TEMP, IBP and
Pulse Rate
• 40 seconds full-disclosure waveforms review
• Maximum 72-hour graphic and tabular trends of all parameters
• Built-in recorder and battery
• Suitable for adult, pediatric and neonatal patient
• Networkable with Hypervisor III and Hypervisor VI Central
• Monitoring Systems
|
|
PM-9000 EXPRESS PATIENT MONITOR
• 12.1” color TFT display with 8 waveforms
• Large font display
• SpO2 pulse-tone modulation (Pitch Tone)
• 12-lead ECG analysis
• Microstream™ EtCO2 (Oridion) / Sidestream EtCO2 (Mindray)
• Masimo SET™ /Nellcor OxiMax™ /Mindray SpO2
• Fixed compact flash for memory card or wireless LAN card
• Li-ion / lead acid battery
• Networkable with Hypervisor VI Central Monitoring System
|
|
MEC-1000 PATIENT MONITOR
• 10.4" color TFT display, with 4 waveforms
• Parameters including ECG/RESP, SpO2, NIBP, TEMP and Pulse
Rate
• SpO2 pulse-tone modulation (Pitch Tone)
• Maximum 72-hour graphic and tabular trends of all parameters
• Built-in recorder and battery
• Suitable for adult, pediatric and neonatal patient
• Networkable with Hypervisor VI Central Monitoring System |
|
PM-6000 MODULAR PATIENT MONITOR
• 12.1" Color TFT display with maximum 8 waveforms
• Arrhythmia, multi-lead S-T segment analysis and pacemaker
detection
• OxyCRG software
• 40 seconds full-disclosure waveforms review
• Drug dose calculation
• Bed to bed view
• Masimo SET™/Mindray SpO2
• Sidestream / Mainstream EtCO2
• Networkable with Hypervisor III and Hypervisor VI Central
Monitoring Systems |
|
PM-600 NIBP/SpO2 PATIENT MONITOR
• Compact and portable, allowing for uninterrupted monitoring
with built-in battery
• Display of NIBP, SpO2 and Pulse Rate via LED with high
brightness
• 3 configurations selectable
• Manual/auto/continuous measurement of NIBP
• Auto audible and visual alarms
• Storage of NIBP data up to 650 groups or SpO2 data up to 10
hours
• External printer available
• Suitable for adult, pediatric and neonatal patient
|
|
VS-800 VITAL SIGN MONITOR
• Suitable for adult, pediatric and neonatal patients
• Masimo SETTM / Nellcor OxiMaxTM / Mindray SpO2
• SmarTempTM thermometer
• Adjustable audible and visual alarms
• Central station networking
• Removable and rechargeable battery, up to 10-hour working
time
• Integrated handle and full mounting solutions |
|
PM-50 PULSE OXIMETER
• Compact, light for carrying and handling
• Automatic Standby, Power-off and Record Management
• Up to 100 patient IDs and 200 records storage
• Data transfer to PC for storage or printing
• Convenient AA size alkaline or rechargeable batteries
• Suitable for adult, pediatric and neonatal patients |
|
|
GIMAITALY PRODUCTS |
|
DIATERMOCOAGULATOR MB 122 - mono-bipolar - 120 Watt
MB 122 and MB 160 are HF electrosurgical units suitable to
effect middle monopolar or bipolar electrosurgery.
By selection of the modes of operation MB 122 and MB 160
provide pure cut, coagulated cut, forced coagulation, soft
coagulation and, with forceps, bipolar coagulation. The use
of either split or normal neutral plate is allowed.
MB 160 is recommended in case of damp operational field, for
instance mucous, or with tissue whose composition is varying
with consequent need to have a reserve of usable power. For
these reasons MB160 is suggested for Gynaecological and
orthopaedic surgery.
Leading-Edge Technology. These advanced concept devices
enable highly professional surgery intervention thanks to
ergonomic and safety features derived from high power
theatre apparatus.
Complete safety. Open Circuit (OC) Alarm warns the user that
connection into the neutral plate has not been made or that
the cable is disconnected or the neutral plate is not in
contact with the patient. The alarm is signalled by an
intermittent beep together with a flashing red light on the
front panel. In this condition HF emission for cut and
coagulation operation is switched off.
OVT Alarm. The unit incorporates an internal circuit
protection warns when the current delivery last too much
long. |
|
DIATERMO MB 132 - mono-bipolar - 120 Watt
HF electrosurgical unit suitable to perform middle monopolar
or bipolar electrosurgery. By selection of the modes of
operation MB 132 provides pure cut, coagulated cut, forced
coagulation, soft coagulation and, with forceps, bipolar
coagulation.
The use of either split or normal neutral plate are allowed.
Technology and precision: Using the digital keyboard MB 132
enables the user to regulate the HF emission time in cut or
coagulation mode with great precision, and to reproduce a
previous intervention.
Moreover it includes a useful “repeat” function which
enables the user to repeat set impulses from 2 to 9 times,
and a timer to monitor the elapsed time of the treatment or
the whole operation.
Complete safety: an acoustic alarm (intermittent beep) and a
blinking red led on front panel warns user that the neutral
plate is unplugged or not in contact with the patient or the
cable is disconnected. In this condition HF emission for cut
and coagulation operation is switched off.
OVT Alarm: the unit incorporates an internal circuit
protection to warn when the current delivery lasts too long.
|
|
DIATERMO MB 160 - mono-bipolar 160 Watt
MB 122 and MB 160 are HF electrosurgical units suitable to
effect middle monopolar or bipolar electrosurgery.
By selection of the modes of operation MB 122 and MB 160
provide pure cut, coagulated cut, forced coagulation, soft
coagulation and, with forceps, bipolar coagulation. The use
of either split or normal neutral plate are allowed.
MB 160 is recommended in case of damp operational field, for
instance mucous, or with tissue whose composition is varying
with consequent need to have a reserve of usable power. For
these reasons MB160 is suggested for Gynaecological and
orthopaedic surgery.
Leading-Edge Technology. This advanced concept device
enables highly professional surgery intervention thanks to
ergonomic and safety features derived from high power
theatre apparatus.
Complete safety. Open Circuit (OC) Alarm warns the user that
connection into the neutral plate has not been made or that
the cable is disconnected or the neutral plate is not in
contact with the patient. The alarm is signalled by an
intermittent beep together with a flashing red light on the
front panel. In this condition HF emission for cut and
coagulation operation is switched off.
OVT Alarm. The unit incorporates an internal circuit
protection warns when the current delivery last too long. |
|
|
OTHER PRODUCTS EXCLUSIVELY SOLD |
Nebulizer |
Stethoscopes |
Examination light |
Head light system |
Operation table and lights system |
Ultrasound Machine |
Transport Ventilator |
High and Low suction machine (portable or wall
mounted ) |
ECG machine |
Patient Monitors |
Diathermy Machine |
Pulse Oximeter |
Diagnostic set (Otoscope/Ophthalmoscope) |
B.P SET |
Phototheraphy Units |
G.A Machine |
|
*Product
Specifications & description subject to change. Please refer
manufacturers website for the latest specifications.
|